How to Read an NFRC Label: U-Factor, SHGC, VT and Air Leakage Explained

Aluminum Windows › North America guide

An NFRC label is a product-specific performance summary issued under the National Fenestration Rating Council program. It reports the U-factor, solar heat gain coefficient (SHGC), visible transmittance (VT), and — where rated — air leakage and condensation resistance for one tested frame, glass and spacer combination. The label tells you what the product scored; the NFRC Certified Product Directory (CPD) tells you whether the score is real, current, and attached to the product you are buying.

Key takeaways

  • NFRC ratings are product-specific: the CPD number and product code matter more than the brand name.
  • U-factor measures whole-unit heat flow; lower is better. SHGC direction depends on climate, not on a universal “lower is better” rule.
  • The certificate holder may be the factory rather than the brand — ask for the relationship in writing.
  • An NFRC label does not cover structural, water or impact performance; those are separate tests.

The five ratings on an NFRC label

Not every label shows all five. U-factor, SHGC and VT are the core ratings; air leakage and condensation resistance appear when the product has been rated for them.

Rating What it measures Units Better direction Typical range
U-factor Heat flow through the whole unit (frame + glass + spacer) Btu/h·ft²·°F Lower 0.17–0.60 for insulating glass
SHGC Fraction of solar heat that enters the room 0–1 Depends on climate 0.05–0.60
VT Fraction of visible light transmitted 0–1 Higher for daylight 0.05–0.70
Air leakage Air infiltration through the assembly at 75 Pa cfm/ft² Lower 0.05–0.30
Condensation resistance Relative resistance to frame and edge condensation 0–100 Higher 30–70

U-factor

U-factor is the whole-product heat transfer rate. Lower is better. It is not the same as the glass-only U-value printed by a glass supplier: the frame, thermal break, spacer and edge-of-glass details all affect the number.

U-factor and R-value are reciprocals: R = 1 ÷ U. A U-factor of 0.30 is roughly R-3.3; a U-factor of 0.20 is R-5.0.

SHGC

SHGC is the share of solar heat that passes through the window. A SHGC of 0.25 means 25% of the sun’s heat enters. In cooling-dominated climates, lower is better. In heating-dominated climates, a higher SHGC can reduce heating load — which is why ENERGY STAR sets a minimum SHGC in the Northern zone and a maximum in the Southern zone.

VT

VT is the share of visible light transmitted. Higher VT means more daylight and a brighter room, but VT and SHGC usually trade off: a dark Low-E coating that blocks heat also blocks light. A window with SHGC 0.12 and VT 0.11 is heavily tinted; one with SHGC 0.30 and VT 0.37 is closer to neutral.

Air leakage

Air leakage is measured at a 75 Pa pressure difference (about 1.57 psf) under NFRC 400. Lower is better, especially on windy sites and tall buildings. The NFRC rating class is usually expressed as ≤0.30, ≤0.10 or ≤0.03 cfm/ft².

Condensation resistance

Condensation resistance (CR) is a relative index from 0 to 100, not a temperature. Higher numbers mean the frame and glass edge stay warmer in winter, reducing sweating and mould risk. CR is useful for cold climates and high-humidity interiors, but it does not replace a dew-point calculation for a specific project.

What the label does not tell you

An NFRC label is a thermal and optical rating. It does not cover:

  • Structural performance — design pressure, deflection and wind-borne debris are covered by NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) and ASTM E330.
  • Water penetration — tested separately under ASTM E331, ASTM E547 or AAMA 501.
  • Impact resistance — Miami-Dade NOA, TAS 201/202/203, or AAMA 506.
  • Security — forced-entry resistance is a different standard (for example, EN 1627 or ASTM F476).
  • Durability of the finish — AAMA 2605 or Qualicoat performance is a separate specification.
  • Installation quality — the best-rated window leaks if the rough opening, flashing and sealant details are wrong.

A supplier who presents an NFRC label as proof of structural or impact performance is either confused or hoping you are.

How to verify an NFRC claim in four steps

Step 1: Ask for the CPD number, not just a label photo

The CPD number is the identifier used in the NFRC directory. It looks like GCH-M-2 (the product line) or GCH-M-2-00004-00001 (a specific product code). A label photo can be copied; a directory entry can be checked.

Step 2: Search the NFRC directory

Go to search.nfrc.org and search by CPD number or manufacturer name. The entry lists the manufacturer, series, operator type, air leakage class, and every rated product code with its U-factor, SHGC, VT and CR.

Step 3: Match the exact product code and glass package

This is where most mistakes happen. A single series can carry 19–20 rated glass configurations, and across the four Starveil series the certified U-factor spans 0.17 to 0.93 depending on the glass package. The number on the quote must match the number on the CPD row for the glass package being supplied — not the best row in the table, and not a different series.

Step 4: Check the certificate holder and expiration date

The CPD entry names the certificate holder, which may be the factory rather than the brand on the brochure. That is normal in private-label and OEM supply, but the relationship should be disclosed. Also check the certification expiration date; an expired rating is not a rating.

Red flags in a supplier’s NFRC claim

  • “NFRC tested” instead of “NFRC certified.” Testing is an input; certification requires an accredited inspection agency, a certificate and a CPD listing.
  • No CPD number. A label without a verifiable directory entry is a picture, not evidence.
  • A rating quoted for a different glass package. Ask for the product code and the glass build-up in writing.
  • A certificate holder with no explanation. If the certificate is under a different company name, ask for the commercial relationship in writing.
  • An expired certificate. CPD listings have expiration dates; check them.
  • “Center-of-glass U-value.” That is a glass number, not a whole-window rating. NFRC U-factor includes the frame.
  • A U-factor with no units. Btu/h·ft²·°F and W/m²K are different numbers; a unitless claim is not usable.

Worked example: reading a real CPD entry

The Starveil 113 casement is listed as CPD GCH-M-2. One rated configuration is GCH-M-2-00004-00001:

Field Value
Manufacturer Guangdong Chuanggao Home Technology Co., Ltd.
Series 113 Casement Window
Operator type CSSV (casement, single vent)
Glass code 6 mm DG4106-01 Low-E + argon + 6 mm Low-E + argon + 6 mm clear
U-factor 0.30 Btu/h·ft²·°F
SHGC 0.12
VT 0.11
Condensation resistance 64
Air leakage (separate NFRC 400 report) 0.24 cfm/ft² net at 75 Pa

Read as: a whole-unit U-factor of 0.30, a dark Low-E package that blocks 88% of solar heat but also cuts visible light to 11%, strong condensation resistance, and air leakage well inside the ≤0.30 class. If the project needs more daylight, the next glass package in the same CPD may give VT 0.37 at U 0.34 — a different trade-off, not a better or worse product.

Starveil and Guangdong Chuanggao Home Technology Co., Ltd. are partner companies. The certificate is held by Chuanggao and used by Starveil under that partnership; the product code on the quote is the link between the two.

What to put in your specification

A useful spec clause does not say “NFRC certified.” It says which rating, which product code, and which standard:

Aluminum windows shall be NFRC-certified and listed in the NFRC Certified Product Directory. U-factor shall not exceed 0.30 Btu/h·ft²·°F and SHGC shall not exceed 0.25 for the specified glass package, as rated under NFRC 100 and NFRC 200. Air leakage shall not exceed 0.30 cfm/ft² when tested to ASTM E283 / NFRC 400. Submit the CPD number, certificate, and test reports for the exact product code supplied.

Add structural and water requirements separately, referencing NAFS class/PG and ASTM E330/E547. Do not rely on the NFRC label for those.

Frequently asked questions

Is NFRC certification mandatory?

It depends on the code and the program. The IECC and many state and local codes reference NFRC ratings for U-factor and SHGC compliance, and utility rebate programs usually require them. Some jurisdictions accept alternative compliance paths. Check the code edition adopted in your project location.

What is a good U-factor for an aluminum window?

For a heating-dominated climate, 0.20–0.25 is high-performance; 0.30–0.35 is mid-range; above 0.40 is hard to justify in a cold zone. In a cooling-dominated climate, SHGC usually matters more than the last 0.05 of U-factor. The right target depends on the whole-wall assembly, not the window alone.

Why is the certificate holder different from the brand?

Private-label and OEM supply is common: the factory holds the NFRC certificate and the seller uses its own brand. That is acceptable if the relationship is disclosed and the product code on the quote matches the CPD. It becomes a problem when the seller cannot explain the link.

Does an NFRC label cover impact resistance?

No. Impact resistance is a separate certification, such as a Miami-Dade County Notice of Acceptance (NOA) or TAS 201/202/203 testing. An NFRC label says nothing about wind-borne debris.

Can a supplier use the best row in the CPD for marketing?

They can quote any rated configuration, but the number must match the product being sold. Quoting the best U-factor in a 20-row table while supplying a different glass package is misleading. Ask for the product code.

Does the NFRC rating include installation?

No. NFRC rates the product as tested in a laboratory opening. Installation, flashing, sealant and rough-opening preparation are site-specific and are not part of the rating.

Check a supplier’s NFRC claim before you sign

Send us the CPD number or the label photo you have been given. We will tell you which product code it corresponds to, what glass package it covers, and whether the rating is current — even if you are comparing us against another supplier.

Request a verification · See Starveil’s NFRC listings · Download the U-factor chart

Ready to Get Your Project Started?

Get A Free Quote
Kael
About the Author

Kael

I assist 4000+ homeowners, designers, and developers source full building material & furniture packages from China, specializing in windows, doors and curtain wall systems — lower risks, consolidated vendors, transparent project delivery.
Why Trust Me:
・5+ Years in building materials & facade engineering
・Core expertise: aluminum windows, doors & curtain walls

Get A Free Quote

Kindly send us your project details and floor plan. We will quote for you within 24 hours!

Call Center

Tel: +86 19928220651

WhatsApp: +86 19928220651

Our Location

Foshan Starveil Building Materials Technology Co., Ltd.

Get in touch

If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.