Aluminum Window U-Factor Chart by Climate Zone (ENERGY STAR v7.0, 2026)
Aluminum Windows › North America guide
U-factor requirements depend on climate zone, and the U-factor alone is not enough: a window must meet both the U-factor and the SHGC threshold for its zone. Under ENERGY STAR v7.0, the prescriptive U-factor limits are 0.22 for the Northern zone, 0.25 for North-Central, 0.28 for South-Central and 0.32 for Southern. Starveil’s NFRC-certified aluminum windows span U-factors from 0.17 to 0.55, so the right glass package changes with the project location — and a very low-SHGC package that qualifies in Miami can fail the Northern zone’s minimum SHGC.
Key takeaways
- ENERGY STAR v7.0 prescriptive U-factor limits: 0.22 / 0.25 / 0.28 / 0.32 for Northern / North-Central / South-Central / Southern.
- The Northern zone is the only one with a minimum SHGC (0.17); the other three cap SHGC.
- A low U-factor can still fail the zone if the SHGC is wrong — check both numbers.
- Starveil’s certified packages span U 0.17–0.55; the frame is not the variable, the glass package is.
What U-factor measures — and what it does not
U-factor is the whole-unit heat transfer rate in Btu/h·ft²·°F. It includes the frame, thermal break, glass, spacer and edge-of-glass details. Lower is better.
It is not:
- The glass-only U-value. A glass supplier’s center-of-glass number will always look better than the NFRC whole-unit rating.
- A measure of solar heat. That is SHGC.
- A measure of air leakage. That is NFRC 400.
- A measure of condensation resistance. That is CR.
U-factor and R-value are reciprocals: R = 1 ÷ U. A U-factor of 0.25 is R-4; 0.20 is R-5; 0.17 is about R-5.9.
ENERGY STAR v7.0 thresholds by climate zone
ENERGY STAR v7.0 uses four climate zones for residential windows. The prescriptive criteria are:
| Zone | Representative locations | U-factor | SHGC | Most Efficient |
|---|---|---|---|---|
| Northern | Buffalo, Chicago, Boston | ≤ 0.22 | ≥ 0.17 | U ≤ 0.20, SHGC ≥ 0.20 |
| North-Central | St. Louis, Kansas City | ≤ 0.25 | ≤ 0.40 | U ≤ 0.20, SHGC ≤ 0.40 |
| South-Central | Atlanta, Charlotte | ≤ 0.28 | ≤ 0.23 | U ≤ 0.20, SHGC ≤ 0.23 |
| Southern | Miami, Houston, Phoenix | ≤ 0.32 | ≤ 0.23 | U ≤ 0.21, SHGC ≤ 0.23 |
Source: ENERGY STAR climate-zone criteria for residential windows, Version 7.0. The Northern zone also has equivalent-performance paths (for example, U 0.23–0.26 with a higher SHGC); the table shows the prescriptive path. The Southern Most Efficient path also allows U 0.22 with SHGC ≤ 0.21. ENERGY STAR is a voluntary qualification program, not a building code. Local code — IECC, California Title 24, Florida Building Code, or a Canadian provincial code — may be stricter.
The Northern zone is the only one with a minimum SHGC. That is deliberate: in a heating-dominated climate, solar gain reduces heating load, so a window that blocks too much sun can be counterproductive even if its U-factor is excellent.
Starveil NFRC U-factors by series and glass package
The values below come from the NFRC Certified Product Directory for the 108, 113, 88 and 128 series. Each row is a specific rated glass package, not a marketing average.
| Series | Glass package | U-factor | SHGC | VT | CR |
|---|---|---|---|---|---|
| 108 casement | Triple Low-E, argon | 0.20 | 0.16 | 0.28 | 71 |
| 108 casement | Double Low-E (DG4106), argon | 0.27 | 0.15 | 0.22 | 67 |
| 108 casement | Double Low-E (TG4110), argon | 0.23 | 0.09 | 0.11 | 71 |
| 113 casement | Triple Low-E, argon | 0.25 | 0.08 | 0.05 | 65 |
| 113 casement | Double Low-E (DG4106), argon | 0.30 | 0.12 | 0.11 | 64 |
| 88 fixed | Triple Low-E, argon | 0.17 | 0.31 | 0.40 | 65 |
| 88 fixed | Double Low-E (DG4106), argon | 0.20 | 0.15 | 0.15 | 67 |
| 128 sliding door | Triple Low-E, argon | 0.28 | 0.29 | 0.36 | 42 |
| 128 sliding door | Double Low-E (DG4106), argon | 0.31 | 0.14 | 0.14 | 42 |
Source: NFRC CPD entries GCH-M-1 (108), GCH-M-2 (113), GCH-M-4 (88) and GCH-M-3 (128). U-factor in Btu/h·ft²·°F. Glass package descriptions are abbreviated; the exact product code and glass build-up must be confirmed in the CPD before ordering.
Which packages meet which zone
This matrix applies both the U-factor and the SHGC threshold. A check mark means the package meets the prescriptive U and SHGC criteria for that zone — not that the finished window is ENERGY STAR certified, which also depends on the complete product and program registration.
| Package | U | SHGC | Northern | North-Central | South-Central | Southern |
|---|---|---|---|---|---|---|
| 108 triple | 0.20 | 0.16 | — (SHGC) | ✓ | ✓ | ✓ |
| 108 double DG4106 | 0.27 | 0.15 | — | — (U) | ✓ | ✓ |
| 108 double TG4110 | 0.23 | 0.09 | — (U) | ✓ | ✓ | ✓ |
| 113 triple | 0.25 | 0.08 | — (U) | ✓ | ✓ | ✓ |
| 113 double DG4106 | 0.30 | 0.12 | — | — (U) | — (U) | ✓ |
| 88 triple | 0.17 | 0.31 | ✓ | ✓ | — (SHGC) | — (SHGC) |
| 88 double DG4106 | 0.20 | 0.15 | — (SHGC) | ✓ | ✓ | ✓ |
| 128 triple | 0.28 | 0.29 | — | — (U) | — (SHGC) | — (SHGC) |
| 128 double DG4106 | 0.31 | 0.14 | — | — (U) | — (U) | ✓ |
Three patterns stand out:
- The 108 triple is a near-miss in the Northern zone. U 0.20 clears the 0.22 limit, but SHGC 0.16 misses the 0.17 floor by one point. A slightly higher-SHGC coating, or the Northern equivalent-performance path, would change the answer.
- The 88 fixed window is the easiest path to the Northern zone. U 0.17 with SHGC 0.31 clears both thresholds, and the fixed unit also avoids operable-sash air leakage.
- Low-SHGC glass is a Southern tool, not a universal upgrade. The 113 triple has an excellent U-factor of 0.25 but SHGC 0.08, so it fails the Northern SHGC minimum and comfortably clears the 0.23 maximum in the South. In the North it would block useful winter sun.
The SHGC side of the equation
Most buyers focus on U-factor and treat SHGC as a secondary number. In practice, SHGC drives cooling load, glare and comfort, and it is the criterion most likely to disqualify a package.
- Northern zone: SHGC ≥0.17. A very dark Low-E coating can fail this even with a great U-factor.
- North-Central: SHGC ≤0.40. Most Low-E packages pass; clear glass may not.
- South-Central and Southern: SHGC ≤0.23. This is where dark Low-E, spectrally selective coatings and triple silver layers earn their cost.
A useful rule of thumb: in cooling-dominated zones, target SHGC first and then choose the cheapest glass package that meets the U-factor. In heating-dominated zones, choose the U-factor first, then check that SHGC is high enough to keep useful solar gain.
Condensation resistance is the third number
CR runs from 0 to 100 and reflects how well the frame and glass edge resist condensation. It is not a temperature and it is not a substitute for a dew-point calculation, but it is a useful screen:
- CR below 40: risk in cold climates or high-humidity interiors.
- CR 40–55: acceptable in mild climates with good ventilation.
- CR above 60: better margin for cold frames and humid rooms.
The 128 sliding door sits at CR 42, which is normal for a sliding track with a large glass area. The 108 and 88 fixed units reach CR 65–71 with warm-edge spacers and triple glazing.
Worked example: the same product in four cities
| Project location | Zone | Candidate package | Result |
|---|---|---|---|
| Buffalo, NY | Northern | 108 triple, U 0.20 / SHGC 0.16 | U passes, SHGC fails by 0.01 — choose a higher-SHGC coating or the 88 fixed triple |
| St. Louis, MO | North-Central | 108 triple, U 0.20 / SHGC 0.16 | Passes both |
| Atlanta, GA | South-Central | 108 double, U 0.27 / SHGC 0.15 | Passes both; 128 triple fails on SHGC 0.29 |
| Miami, FL | Southern | 128 double, U 0.31 / SHGC 0.14 | Passes both; 88 triple fails on SHGC 0.31 |
The lesson is not that one series is better. It is that the glass package, not the frame brand, decides compliance — and the same frame can be right in one zone and wrong in another.
Specification checklist
- ☐ Confirm the project climate zone and the adopted code edition.
- ☐ Set a maximum U-factor and a maximum or minimum SHGC, not just “ENERGY STAR compliant.”
- ☐ Require the NFRC CPD number and the exact product code for the supplied glass package.
- ☐ Require air leakage and water penetration separately (NFRC 400, ASTM E283/E547).
- ☐ Require structural performance separately (NAFS class/PG, ASTM E330).
- ☐ Check the SHGC direction: minimum in the North, maximum in the South.
- ☐ Confirm condensation resistance for cold or humid interiors.
- ☐ Require a submittal with the CPD printout and the certificate, not a brochure.
Frequently asked questions
Is ENERGY STAR the same as the building code?
No. ENERGY STAR is a voluntary qualification program. The IECC and state or local codes set the enforceable U-factor and SHGC limits, and they may be stricter or follow a different compliance path. Use ENERGY STAR as a benchmark, then verify the adopted code.
What U-factor do I need in climate zone 5?
Zone 5 falls within the Northern zone for ENERGY STAR v7.0, where the prescriptive U-factor limit is 0.22 and the SHGC minimum is 0.17. Some codes set a different limit, so check the code edition adopted in the jurisdiction.
Can I use a low-SHGC window in a cold climate?
It will meet the U-factor if the glass package is good enough, but it may fail the Northern SHGC minimum and it will reduce passive solar gain. In a heating-dominated climate, a very dark Low-E coating is often a poor trade-off unless summer overheating or glare is the dominant problem.
Does triple glazing always beat double glazing?
Not automatically. A well-built double unit with a warm-edge spacer and a good frame can outperform a poorly built triple unit. Triple glazing adds weight, cost and thickness; it makes the most sense in cold climates, noisy sites, or projects targeting the lowest possible U-factor.
Why do two windows with the same U-factor have different SHGC?
U-factor and SHGC are separate properties. The Low-E coating, the number of silver layers, the glass tint and the gas fill affect them differently. Two packages can both reach U 0.30 while one transmits 0.12 solar heat and the other 0.30.
Where can I verify the U-factor and SHGC values?
Use the NFRC Certified Product Directory at search.nfrc.org. Search by CPD number (for example, GCH-M-2) and match the exact product code and glass package. Manufacturer brochures are not a substitute for the directory entry.
Get a climate-zone recommendation
Send your project location, window schedule and target code. We will return a proposed glass package for the zone, the matching NFRC CPD codes, and a line-item quote — with the U-factor and SHGC trade-offs stated explicitly.
Request a quote · How to read an NFRC label · Aluminum window specification guide