Aluminum Window Specification Guide (CSI 08 51 13) for North American Projects
Aluminum Windows › North America guide
CSI 08 51 13 — Aluminum Windows is the MasterFormat section that governs aluminum window systems: performance requirements, materials, fabrication, finishes, glazing, hardware, submittals and installation. A defensible spec does three things at once: it states measurable performance (NFRC ratings, NAFS class and PG, air and water limits), it requires proof for the exact product being supplied (CPD number, test reports, calculations), and it makes installation and field testing part of the contract. This guide explains how to structure the section and includes copy-paste language for the most commonly missed clauses.
Key takeaways
- Specify performance by standard and number, not by adjective: NFRC 100/200/400, NAFS class/PG, ASTM E283/E330/E547.
- Require the NFRC CPD product code and the exact glass package, not a generic “NFRC certified” claim.
- Keep thermal performance (NFRC) separate from structural and water performance (NAFS, ASTM E330/E547).
- Make field water testing and air-barrier coordination part of the contract, not an afterthought.
What 08 51 13 covers — and what it does not
Section 08 51 13 covers factory-assembled aluminum windows and their components: frames, sashes, operable hardware, glazing, weatherstripping, screens, anchors and accessories.
It does not cover:
- Curtain walls — use 08 44 13 Glazed Aluminum Curtain Walls.
- Storefronts and entrances — use 08 41 13 Aluminum-Framed Entrances and Storefronts.
- Glazing as a separate scope — 08 81 00 Glazing.
- Air barrier and flashing — 07 27 00 Air Barriers and 07 92 00 Joint Sealants, coordinated with 08 51 13.
- Structural mullion design — the window spec can require calculations, but the loads come from ASCE 7 and the project structural engineer.
A common failure mode is a spec that puts curtain-wall performance requirements into a window section, or leaves air barrier and flashing to “by others” without defining the interface. Both create gaps at the rough opening.
The three-part structure
Part 1 — General
Part 1 sets the rules: related work, submittals, quality assurance, delivery, storage, warranty and project conditions.
Require at minimum:
- Product data for each window type, including frame depth, profile series, glass build-up and hardware.
- Shop drawings with elevations, sections, head/sill/jamb details, anchor locations, opening sizes and interface with the air barrier.
- Structural calculations for mullions, anchors and connections at the project design pressure.
- NFRC documentation — the CPD number, the certificate and the exact product code for the supplied glass package.
- Test reports for air, water and structural performance.
- Samples of finish, glass, hardware and weatherstripping.
- Mock-up if the project has repetitive or high-exposure conditions.
- Warranty terms for the frame finish, insulating glass and hardware.
Part 2 — Products
Part 2 is where most specs are won or lost. It should define performance by standard and by number, not by adjective.
Performance requirements to state explicitly:
| Requirement | Standard | Typical specification |
|---|---|---|
| U-factor | NFRC 100 | ≤ the code limit for the climate zone; state the exact number |
| SHGC | NFRC 200 | ≤ or ≥ the code limit, depending on zone |
| Air leakage | ASTM E283 / NFRC 400 | ≤ 0.30 cfm/ft²; ≤ 0.10 for high-performance |
| Water penetration | ASTM E331 or E547 | No uncontrolled water penetration at the project design pressure |
| Structural performance | ASTM E330 | No permanent deformation at 1.5 × design pressure; deflection ≤ L/175 |
| Performance class and grade | AAMA/WDMA/CSA 101/I.S.2/A440 (NAFS) | Class and PG appropriate to the building height and exposure |
| Condensation resistance | NFRC | Minimum CR for the project condition |
| Acoustics | ASTM E90 / E413 / E1332 | STC or OITC if the project requires it |
| Finish | AAMA 2605 (or 2604/2603 as appropriate) | Specify the exposure and color/gloss retention |
| Insulating glass | ASTM E2190 | Required for dual-pane and triple-pane units |
Worked example. The 113 casement + 88 fixed assembly is tested to Class CW-PG100 at ±4,800 Pa, with water penetration resistance at 720 Pa and air leakage of 0.02 L/s·m² (fixed) and 0.04 L/s·m² (casement) at ±75 Pa. The Intertek report is 260121109GZC-001. A specification for a similar assembly can reference this report directly instead of writing a generic “commercial grade” clause.
Materials:
- Aluminum extrusions: 6063-T5 or 6063-T6, with a minimum wall thickness appropriate to the structural requirement.
- Thermal break: polyamide (PA66) with a minimum width matched to the U-factor target.
- Glass: ASTM C1036 for flat glass, C1048 for heat-treated, C1172 for laminated; specify Low-E coating, gas fill, spacer and edge seal.
- Hardware: specify the brand, material and cycle test; stainless or high-grade plated for coastal projects.
- Fasteners and anchors: stainless steel or hot-dip galvanized, isolated from aluminum where galvanic corrosion is a risk.
- Sealants: compatible with the frame finish and the adjacent air barrier.
Finishes:
- AAMA 2605 for high-performance PVDF coatings in demanding exposures.
- AAMA 2604 for standard exterior exposure.
- AAMA 611 for anodized finishes.
- Specify color, gloss range and touch-up procedure.
Part 3 — Execution
Part 3 covers examination, installation, field quality control, cleaning and protection.
Require:
- Examination of rough openings before installation: dimensions, square, level, plumb, and condition of the air barrier and flashing.
- Installation per the manufacturer’s written instructions and the approved shop drawings.
- Field water testing on a sample of installed units, especially on high-rise, coastal or hurricane-exposed projects. Reference AAMA 501.2 for field water testing.
- Air leakage field testing where the project requires it.
- Cleaning and protection of finishes and glass at completion.
- As-built documentation and O&M manuals.
Copy-paste spec language
The following paragraphs can be adapted into Part 1, 2 and 3. Bracketed values are project-specific.
Part 1 — Submittals
Submit product data, shop drawings, structural calculations, NFRC Certified Product Directory (CPD) printouts, certificates and test reports for each window type. The CPD printout shall identify the product code and glass package being supplied. Test reports shall include air leakage (ASTM E283 / NFRC 400), water penetration (ASTM E331 or E547) and structural performance (ASTM E330). Submit finish samples, glass samples and hardware samples for approval before fabrication.
Part 2 — Performance requirements
Aluminum windows shall be NFRC-certified and listed in the NFRC Certified Product Directory. U-factor shall not exceed [0.30] Btu/h·ft²·°F and SHGC shall not exceed [0.25], as rated under NFRC 100 and NFRC 200 for the specified glass package. Air leakage shall not exceed [0.30] cfm/ft² when tested to ASTM E283 / NFRC 400. Water penetration shall not occur at [720] Pa when tested to ASTM E547 or ASTM E331. Structural performance shall meet ASTM E330 at a design pressure of [±4,800] Pa, with deflection not exceeding L/175. Windows shall meet NAFS Class [CW] — PG [100] for the tested size and configuration.
Part 2 — Materials and finishes
Aluminum extrusions shall be 6063-T5 or 6063-T6. Thermal breaks shall be polyamide (PA66) of a width required to achieve the specified U-factor. Exposed aluminum surfaces shall receive a [PVDF fluorocarbon] finish meeting AAMA [2605], in the specified color. Glass shall be [Low-E, argon-filled, tempered or laminated] insulating glass meeting ASTM E2190, with a warm-edge spacer. Hardware shall be [brand/model], tested to [cycle count], and shall be stainless steel or high-grade plated for coastal exposure.
Part 3 — Installation and field testing
Install windows plumb, level and square in accordance with the approved shop drawings and the manufacturer’s written instructions. Coordinate flashing and sealant with the air barrier and waterproofing systems. Field water test [10]% of installed units, and not fewer than [three] units, in accordance with AAMA 501.2. Correct any water penetration and retest before close-out. Protect finishes and glass until substantial completion.
Common specification mistakes
- “NFRC certified” with no product code. The CPD covers specific glass packages; a generic claim is unverifiable.
- U-factor and SHGC directions reversed. In the Northern zone, SHGC is a minimum; in the Southern zone, it is a maximum.
- A design pressure with no tested size. NAFS ratings apply to the tested size and configuration; larger units need project-specific engineering.
- No structural calculations for mullions. The window supplier should provide them, not leave them to the GC.
- Water penetration specified without a test method. ASTM E331, E547 and AAMA 501 are different tests; state which one and at what pressure.
- Air barrier and flashing left “by others.” Define the interface and require coordination in the submittal.
- “Or equal” without performance criteria. Without measurable criteria, “equal” is a negotiation, not a standard.
- No field testing. Laboratory ratings do not prove the installed assembly is watertight.
Submittal checklist
- ☐ Product data for each window type
- ☐ Shop drawings with head, sill, jamb and anchor details
- ☐ Structural calculations for mullions and anchors
- ☐ NFRC CPD printout with product code and glass package
- ☐ NFRC certificate and expiration date
- ☐ Air, water and structural test reports
- ☐ NAFS test report with class and PG
- ☐ Finish, glass and hardware samples
- ☐ Insulating glass warranty
- ☐ Finish warranty
- ☐ Installation instructions and O&M manuals
- ☐ Field testing plan
Frequently asked questions
What is CSI 08 51 13?
08 51 13 is the MasterFormat section for Aluminum Windows. It covers factory-assembled aluminum window systems, including frames, sashes, hardware, glazing and accessories. Curtain walls (08 44 13) and storefronts (08 41 13) are separate sections.
What NAFS class and PG should I specify?
It depends on building height, exposure and code. Residential projects often use Class R or LC; commercial and high-rise projects typically require Class C, HC or CW with a PG that matches the design pressure. The design pressure comes from ASCE 7 wind loading, not from a default table.
How do I specify NFRC ratings correctly?
State the metric, the limit, the standard and the product code. For example: “U-factor shall not exceed 0.30 Btu/h·ft²·°F per NFRC 100, and SHGC shall not exceed 0.25 per NFRC 200, for the glass package identified by CPD product code [code].” Then require the CPD printout in the submittal.
Is ASTM E331 the same as ASTM E547?
No. E331 is a static water penetration test; E547 is a cyclic static pressure test. AAMA 501.1 is a dynamic test. Specify the method that matches the project’s exposure and the code’s requirement.
Do I need field water testing?
For high-rise, coastal, hurricane-exposed or high-value projects, yes. A laboratory rating proves the design; field testing proves the installation. AAMA 501.2 is the common field water test method.
How do I compare two suppliers’ “equal” products?
Require the same performance criteria, the same test methods and the same submittal package. Compare the NFRC product codes, the NAFS class/PG, the air and water results, the finish system and the hardware — not just the unit price.